EN
Tel: 188-1699-6168()
Address: Room 908, No. 28, Moyu Road, Anting Town, Jiading District, Shanghai

Scan the wechat code for consultation

Current position: Home > Supply

VESTAKEEP® 2000 GF30 | PEEK-GF30 | Evonik Operations GmbH

Release time:2025-06-18Author:小编

VESTAKEEP® 2000 GF30 | PEEK-GF30 | Evonik Operations GmbH

Product Texts

Glass fiber-reinforced (30%), medium viscosity polyether ether ketone

VESTAKEEP®2000 GF30 is a medium-viscosity, glass fiber-reinforced (30%) polyether ether ketone for injection molding.

The semi-crystalline polymer features superior mechanical, thermal, and chemical resistance. Parts made from VESTAKEEP® 2000 GF30 are of low flammability.

VESTAKEEP® 2000 GF30 can be processed by common injection-molding machines for thermoplastics.

We recommend a melt temperature between 380°C and 400°C during the injection molding process. The mold temperature should be within a range of 160°C to 200°C, preferably 180°C.

VESTAKEEP® 2000 GF30 is supplied as cylindrical pellets in 25kg boxes with moisture-proof polyethylene liners.

Pigmentation may affect values.

Inside the original and undamaged packaging, the product has a shelf life of at least 2 years when stored in dry rooms at temperatures not exceeding 30°C.

For information about processing of VESTAKEEP 2000 GF30, please follow the general recommendations in our brochure “VESTAKEEP® PEEK Processing Guidelines“.

The values presented are typical or average values, they do not constitute a specification. 

Rheological properties Value Unit Test Standard
Melt volume-flow rate, MVR 24 cm³/10min ISO 1133
Temperature 400 °C ISO 1133
Load 5 kg ISO 1133
Molding shrinkage, parallel 0.2 % ISO 294-4, 2577
Molding shrinkage, normal 0.7 % ISO 294-4, 2577
Mechanical properties Value Unit Test Standard
Tensile modulus 11000 MPa ISO 527-1/-2
Stress at break 180 MPa ISO 527-1/-2
Strain at break 3 % ISO 527-1/-2
Charpy impact strength, +23°C 55C kJ/m² ISO 179/1eU
Charpy impact strength, -30°C 65C kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 10C kJ/m² ISO 179/1eA
Charpy notched impact strength, -30°C 8C kJ/m² ISO 179/1eA
Thermal properties Value Unit Test Standard
Melting temperature, 10°C/min 340 °C ISO 11357-1/-3
Temp. of deflection under load, 1.80 MPa 323 °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 338 °C ISO 75-1/-2
Vicat softening temperature, 50°C/h 50N 335 °C ISO 306
Coeff. of linear therm. expansion, parallel 30 E-6/K ISO 11359-1/-2
Burning behavior at 1.5 mm nominal thickness V-0 class IEC 60695-11-10
Thickness tested (1.5) 1.6 mm IEC 60695-11-10
Oxygen index 45 % ISO 4589-1/-2
Electrical properties Value Unit Test Standard
Relative permittivity, 100Hz 3.3 - IEC 62631-2-1
Relative permittivity, 1MHz 3.3 - IEC 62631-2-1
Dissipation factor, 100Hz 20 E-4 IEC 62631-2-1
Dissipation factor, 1MHz 40 E-4 IEC 62631-2-1
Volume resistivity >1E13 Ohm*m IEC 62631-3-1
Surface resistivity 1E15 Ohm IEC 62631-3-2
Electric strength 37 kV/mm IEC 60243-1
Comparative tracking index 200 - IEC 60112
Other properties Value Unit Test Standard
Water absorption 0.4 % Sim. to ISO 62
Density 1500 kg/m³ ISO 1183
Test specimen production Value Unit Test Standard
Injection molding, melt temperature 380 °C ISO 294
Injection molding, mold temperature 180 °C ISO 294
Injection molding, injection velocity 200 mm/s ISO 294
Injection molding, pressure at hold 120 MPa ISO 294

Recommended news